Aprilaire 1830 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
Application Sheet 4 – Two Zone using Internal Control
Parts Needed (additional
parts may be required):
__ Model 1830/1850/1870
__ Insulated duct
__ Thermostat wire
__ Duct fittings & hardware
__ 20A Outlet (1870 only)
__ Drain pan and float switch (if
required)
__ Grilles
__ 4522 Damper Kit (includes:
2 – 8” dia N.O. dampers,
2 – 8” dia N.C. dampers and
one 40VA, 24VAC plug-in
transformer)
Figure 1
Duct/Damper Layout with
Whole House as Primary Zone
Figure
2
Duct/Damper Layout with
Basement as Primary Zone
Figure
3
Wiring
Sequence of Operation
Adjust the relative humidity (RH) setting on the
dehumidifier control; this will be the setting for both the
Primary and Secondary Zone. Once an hour, the
dehumidifier will “sample” the air in the Primary Zone.
If there is no need for dehumidification in the Primary
Zone the dehumidifier will then sample the air in the
Secondary Zone.
When sampling in the Primary Zone the dehumidifier
will energize the dampers and then turn on its blower
(and the HVAC System blower if wired as shown in
Figure 3), to measure the RH of the air. If the RH of the
air is above the setting, the compressor will turn on. If
the Primary Zone does not need dehumidification, the
dampers are de-energized and the HVAC System Blower
(if on) is turned off while the dehumidifier blower
continues to run to sample the air in the Secondary
Zone. If the RH of the air in the Secondary Zone is above
the setting, the compressor will turn on.
Set Up the Dehumidifier for Zoning
1. With “OFF” showing on the control, press the Mode button for 3 seconds to enter the Installer Set Up menu
2. Press the Mode button until “ZONE DISABLED” appears.
3. Press the Up or Down button to change to “ZONE ENABLED”.
4. Press the Mode button repeatedly until “DONE” shows on the display.
G
HVAC
EQUIPMENT
THERMOSTAT
R
C
G
W
Y
EXISTING WIRE
NEW WIRE
DH DH
HVAC EQUIP
Gh Rf Cf Gs W Y
FLOAT
SWITCH
DEHUMIDIFIER
CONTROL BOARD
NC
NO
R
C
W
Y
N.C. DAMPERS
120
VAC
24
VAC
20 VA (MIN.)
TRANSFORMER
N.O. DAMPERS
HVAC EQUIPMENT
NORMALLY
CLOSED
DAMPER
NORMALLY
CLOSED
DAMPER
NORMALLY
OPEN DAMPER
NORMALLY
OPEN DAMPER
TO/FROM SECONDARY ZONE
TO BE DEHUMIDIFIED
TO/FROM PRIMARY ZONE TO BE
DEHUMIDIFIED
HVAC EQUIPMENT
NORMALLY
OPEN DAMPER
NORMALLY
OPEN DAMPER
NORMALLY
CLOSED
DAMPER
NORMALLY
CLOSED
DAMPER
TO/FROM PRIMARY ZONE
TO BE DEHUMIDIFIED
TO/FROM SECONDARY ZONE TO
BE DEHUMIDIFIED