APRILAIRE STEAM
The Aprilaire dispersion tube employs tubelets that reach inside the tube and capture the hottest, driest steam and
introduce this into the air stream in a controlled manner. Any condensation that forms in the dispersion tube or the
tubelet is captured and drained out of the duct. Proper dispersion of steam into the air steam insures the humidity is
delivered into the home and not on the duct walls.
The distance the steam absorbs
into the air depends on the air
temperature, RH set point, and air
flow velocity in the duct. In general
if the distance from the dispersion
tube to an obstruction is less than
28” the steam will have enough
distance to absorb into the air. Ifthe
distance is less refer to the chart
to the right.
Applications that do not have
forced air through a duct system to distribute air into the home are typically installed with the Aprilaire Model 850 fan pack.
The Fan Pack is mounted in the conditioned space and distributes the humidity into the air.
Canister Replacement (Model 80)
Canister replacement is recommended every humidifier season. When the canister cannot
reach the correct conductivity, it will stop and wait for the canister to be replaced.
Abnormal water conditions may cause the unit to operate for month or years.
If the canister cannot reach 11.5 amps the unit will shut down, the service light will turn
on and it will wait for the tank to be replaced.
DRI-STEEM's reputation as the commercial/
industrial humidification leader is built on 45 years
of product innovation. Aprilaire has combined
DRI-STEEM's commercial steam humidification
expertise with Aprilaire's residential market
knowledge to produce steam humidifiers perfect
for residential applications where evaporative
technology is not practical.
Region of Waterloo Water
Testing Laboratory
Ontario, Canada
Glenn H. Curtiss Museum
Hammondsport, New York
University of Alberta
Hospitals
Alberta, Canada
TO REMOVE THE CANISTER ITS A SIMPLE PROCEDURE.
1. Turn power off at the unit, it will automatically drain.
2. When draining is complete, turn off electrical to the unit.
3. Remove the front panel
4. Disconnect electrodes, water sensor, and hose clamp at
top of canister
5. Replace canister and provided o-ring