Model 1850F Dehumidifier
Installation and Operating Manual
READ AND SAVE THESE INSTRUCTIONS
CAUTION
1. Read all instructions before beginning installation.
2. Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.
3. Do not use in pool applications. Pool chemicals can damage the dehumidifier.
4. Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
5. Wait 24 hours before running the unit if it was not shipped or stored in the upright position
6. Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation
to lower indoor humidity in the winter.
WARNING
1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing.
Leave power disconnected until installation/service is completed.
2. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
SAFETY INSTRUCTIONS
Dehumidifer Control
ON/OFF button
used to turn
dehumidifier on
and off
Up/Down
buttons used to
change humidity
setting
MODE button
used for optional
ventilation feature
Inlet Filter Access
Door
Drain Power
Switch
Outlet
90-1952
1
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Model 1850F Dehumidifier

Model 1850F DehumidifierInstallation and Operating ManualREAD AND SAVE THESE INSTRUCTIONS CAUTION1. Read all instructions before beginning installati

Page 2 - TABLE OF CONTENTS

SERVICE PARTSNo. Part Description Part No.1 Filter, 12” x 12” x 1” EZK 54992 InternalControlBoard,Deh 54443 UserInterfaceAssembly,Deh 54454 Wiri

Page 3 - LOCATION CONSIDERATIONS

LIMITED WARRANTYWARRANTY REGISTRATIONYour Research Products Corporation Aprilaire® Dehumidifier is expressly warranted for five (5) years from date of

Page 4 - DRAIN INSTALLATION

P.O.Box1467•Madison,WI53701-1467•Phone:800/334-6011 •Fax:608/257-4357•www.aprilairepartners.com10010677 3.14B2206280APrinted in U.S.A.©

Page 5

SPECIFICATIONSModel 1850FWeight70 lbs.Capacity AHAM DH-1-2008 80°F, 60% RH Conditions95 pints per day @ 230 CFMPower 115 VAC, Single Phase, 60Hz8A ope

Page 6 - CAUTION

LOCATION CONSIDERATIONSTOP VIEWFILTERMINIMUMCLEARANCE FOR FILTER(EITHER SIDE)13"6" MINIMUM CLEARANCEFOR PROPER AIR FLOWELECTRICAL SERVICEACC

Page 7 - CONTROL AND WIRING

FLOATSwitchDH DHNORMALLY CLOSEDFLOAT SWITCHDRAIN INSTALLATIONLEVELINGCONDENSATE PAN, CONDENSATE PUMP AND FLOAT SWITCHAlevelsurfaceisrequiredtoen

Page 8 - TROUBLESHOOTING

SETTING THE DESIRED HUMIDITY LEVEL1.PresstheON/OFFbuttontoturnthedehumidifiercontrolON.Thedisplaywillshowthecurrent setting, and the

Page 9 - TROUBLESHOOTING (CONTINUED)

MAINTENANCECLEAN OR REPLACE THE AIR FILTERAfter initial installation the air filter should be checked and cleaned every 6 months. TheCLEANFILTERse

Page 10 - SERVICE PARTS

MODEL 76 – EXTERNAL CONTROL OR CRAWL SPACE/SEALED ATTIC CONTROL AND WIRINGWhenthedehumidifierislocatedinacrawlspace,sealedattic,orotherh

Page 11 - LIMITED WARRANTY

TROUBLESHOOTINGTechnical Support is available Monday through Friday, 7:00 a.m. to 5:00 p.m. CST, at (800) 334-6011. Use the guides on the following pa

Page 12 - Printed in U.S.A

TABLE 2 – Troubleshooting GuideSymptom Possible Reason Troubleshooting ProcedureDehumidifier does not turn on/run.Nopowertounit. • Checkthatthe