Go to www.aprilairecontractor.com to order literature or download product documentation.
6303 Control Panel
PLENUM TEMPERATURE CONTROL (ADJUSTABLE)
Protects equipment from excessive high and low temperatures
caused by reduced airflow when small zones are calling.
THERMOSTAT FLEXIBILITY
Use any four wire heat/cool thermostat in each zone or a heat
pump thermostat in zone one.
L.E.D. STATUS INDICATORS
Simplifies start up and troubleshooting for the contractor.
TIME DELAY OVERRIDE
Speeds checkout for the installer.
WORKS WITH TWO OR THREE WIRE DAMPERS
Compatibility if you are changing out an old panel with
three wire dampers.
ADJUSTABLE PURGE TIMING
Compatibility with all brands of equipment.
ELECTRIC / NON-ELECTRIC SWITCH
Proper control of the fan (G-terminal) for either electric
or fossil fuel furnaces.
Model 6303
6303 Control Panel
THE EASIEST HEAT PUMP CONTROL AVAILABLE
The Model 6303 control panel is designed for single-stage compressor,
heat pump systems only. A single-stage heat/cool (four wire) thermostat
can be used in each zone for the most economical installation solution;
however, a heat pump thermostat can be used in zone one for living space
control of the emergency heat mode. When heat/cool thermostats are used in all zones,
emergency heat is set at the control panel via a convenient switch. Auxiliary heat is controlled by a
fixed timer set for 20 minutes to assure homeowner comfort without expensive heat pump thermostats. The
simplicity and low cost of the Model 6303 make it perfect for new construction applications or existing homes.
Step One: Select A Zoned Comfort Control Panel
ANY ZONE SETS MODE
Provides true independent control for each zone.
CONTINUOUS FAN BY ZONE
Individual zone thermostats can call for fan operation by zone.
ZONE CHANGEOVER BASED ON TIME
If calls for opposite modes exist, the control panel will alternate to
satisfy each call.
FAN PURGE
Assures air is directed to last zone(s) calling.
SHORT CYCLE PROTECTION
Protects the HVAC equipment from too frequent cycling.
MAINTENANCE FREE
No maintenance or adjustments needed after installation.
CONSUMER BENEFITSCONSUMER BENEFITS CONTRACTOR BENEFITS
13
Zones 1–3 Single-Stage Heat/Cool
R (24V-hot)
W (Heat)
Y (Cool)
G (Fan)
Programmable
• Aprilaire Model 8363
• Aprilaire Model 8570
Non-Programmable
• Aprilaire Model 8344
Zone 1 Only
(Provides control of Emergency
Heat from Thermostat)
Single-Stage Heat Pump
R (24V-hot)
O (Reversing Valve-Cool)
W (Auxiliary Heat)
Y (Compressor)
G (Fan)
Programmable
• Aprilaire Model 8365
• Aprilaire Model 8570
Non-Programmable
• Aprilaire Model 8346
ZONE TYPE TERMINALS REQUIRED
*
RECOMMENDED THERMOSTATS
THERMOSTAT REQUIREMENTS
*An available “C” terminal (24-volt common) in each zone of the control panel can be used for 24-volt powered thermostats.