6706 Retrofit Damper
 
Step Two: Select Zoned Comfort Control Dampers
21
Retrofit Damper
Aprilaire
®
has broken open the service and replacement revenue
stream for zoned comfort control with the first-ever, spring-return
damper designed to be inserted in a six inch round branch duct.
Virtually every home without zoning has comfort problems. It is now
affordable to zone these homes without costly, and sometimes
impossible, duct modification.
By offering this simple solution, you provide your customers with
true comfort throughout their home, better than operating constant
fan or manually adjusting registers. You also assure your quality
reputation with enhanced customer satisfaction through increased
comfort and reliable, maintenance-free operation.
PROFITABLE
• You can now provide an economical solution to your customer’s
comfort needs securing more sales.
EASY INSTALLATION
• Simply cut a slot, insert the damper, and screw or strap the damper
to the duct.
INSTALLER FRIENDLY
• High-resolution L.E.D. on the damper illuminates when closed,
simplifying check-out and troubleshooting.
RELIABLE
• “No gears” technology assures long life.
FAIL SAFE
• Spring-open operation assures airflow and minimizes
after-hour callbacks.
Model 6706
COMFORT
• The temperature where and when they want it.
CONVENIENCE
• System is completely automatic. Add programmable thermostats or
the Aprilaire Zoned Comfort Control system for the ultimate
convenience and control.
ENERGY SAVINGS
• It makes sense; don’t waste energy conditioning the whole home,
only condition areas that need it. “Would you have a single light
switch for you entire home?”
CONSUMER BENEFITS CONTRACTOR BENEFITS
DUCT SIZE 6" round
OVERALL SIZE 3.3"(H)x 8.0"(W)x 8.3"(D)
WEIGHT 1 lb.
POWER REQUIREMENT 10 VA @ 24 VAC
RESISTANCE 0.008" W.C. @ 700 fpm
MODEL 6706 - DAMPER SPECIFICATIONS
Model 8028 Power Distribution Panel
• Simplifies installation when the number of dampers exceeds
the fuse rating of the control panel
• Makes troubleshooting easier
• Gives a professional and clean appearance to your installation
MAX. DAMPER POWER INPUT PER ZONE 100 VA @ 24 VAC
DAMPER FUSE SIZE 5 A fast acting (spare supplied)
CONTROL INPUT CURRENT DRAW (ZONE A & B) 50 mA @ 24 VAC
MAX. NO. OF APRILAIRE DAMPERS PER ZONE 10
MAX. WIRE SIZE 18 AWG
APPLICATION TEMPERATURE / RH 140˚F / 90% RH (non-condensing)
MODEL 8028 - POWER DISTRIBUTION PANEL SPECIFICATIONS